JMC 2M2260 Stepper Motor Driver
Product Brand: | HYCNC |
product name: | JMC 2M2260 stepper motor driver |
Operating Voltage: | AC80V-220V |
Applicable motor: | 86, 110 Stepper motor |
Delivery time: | 1-7day |
Product Brand: | HYCNC |
product name: | JMC 2M2260 stepper motor driver |
Operating Voltage: | AC80V-220V |
Applicable motor: | 86, 110 Stepper motor |
Delivery time: | 1-7day |
Features: | 1. Built-in fan cooling 2. Low vibration, low heat generation, stable operation at low speed 3. It is convenient to set the current, which can be arbitrarily selected between 1.3A-5.6A (effective value) 4. With over-voltage, under-voltage, short circuit and other protection functions 5. Ultra-low vibration noise 6. Impulse response frequency up to 200KHz 7. Direct AC220v alternating current |
Instructions for use: | The CNC driver drives the stepper motor. The driver needs to select the power supply according to its supported voltage range. Then the driver is connected with the stepper motor and the control system, and the control system controls the cnc router machine running . |
phenomenon | Possible problem | solution |
The motor does not rotate | Power light is off | Working normal |
Current setting is too small | According to the rated current of the motor, select the appropriate current gear | |
Drive is protected | After the fault is excluded, power on again | |
Control signal problems | Check whether the amplitude and width of the control signal meet the requirements | |
Wrong direction of motor rotation | Wrong connection of motor wire | Arbitrarily exchange two wires of the same phase of the motor (for example, A + A- exchange wiring position) |
Motor wire is broken | Check and connect | |
Alarm indicator light | Wrong connection of motor wire | Check wiring |
The voltage is too high or too low | Check the power supply voltage | |
Damaged motor or driver | Replace motor or driver | |
Inaccurate location | Signal is disturbed | Eliminate interference |
Shielded ground wire is not connected or not connected | Reliable ground | |
Segmentation error | Set subdivision correctly | |
Current is too small | Increase the current appropriately | |
Control signal problems | Check whether the control signal meets the timing requirements | |
Stall when the motor accelerates speed | The acceleration time is too short | Increase the acceleration time appropriately |
Motor torque is too small | Choose high torque motor | |
Low voltage or too low current | Properly increase the voltage or set a larger current |